Our customer has a large log saw with a log feed motor and requires to
optimize efficiency of the cutting operation.
The log feed motor speed is controlled by the 4-20 mA output scaled from the
saw blade motor current. As the saw motor load increases above 90% load, the
log feed motor slows. If the load increases above 120%, the feed motor stops.
If the load increases to 150%, the saw motor stops.
The motor load is represented on the tri-color bargraph. The bargraph scale
indicates 1% steps in motor current, and changes from green to orange at 90%
load and orange to red at 120% load. The digital display indicates saw motor
amps.
|