Our customer manufactures machines for loading produce into bags at preset
weights. A conveyor carries the produce to the bag. The conveyor speed
controller slows the conveyor when the bag nears the required weight. The bag
is hung from a load cell which feeds the weight to the Tiger 320 meter
controller. When the bag is near the required weight, a setpoint in the meter
slows the conveyor. When the bag reaches the required weight, the meter
automatically compensates for produce inertia and determines when to stop the
conveyor and close the conveyor feed gate. The display flashes between
"BAGFUL" and "WEIGHT".
The operator unclamps the bag, and the meter counts and totalizes the bag
number from the bag clamp microswitch pulse. The operator fits a new bag and
the clamp closes after a 1 second delay to stabalize the load cell.
The operator tares the load cell input to 0, cancelling the empty bag weight.
The fill cycle restarts. All program functions not used are blanked out and
the setpoints are titled for ease of operation.
Note: This customer was originally using a panel meter, a PLC and a motor
drive for this application. Using Texmate's Tiger 320 Series controller, a PLC
is no longer required saving both cost and time in manufacturing.
|