Our customer carries out stress tests on beams to determine the peak load
pressure and the linear displacement reading at the point of failure.
Texmate installed a Tiger 320 Series DI-50E meter configured to display and
hold the peak readings, load pressure on Channel 1, and linear displacement on
Channel 2.
The meter is configured to log data at a constant rate and download directly
to a computer to calculate the rate of change
APPLICATION VARIATIONS
- Date, time, load peak pressure, and linear displacement downloaded
directly to a printer, at a timed rate or from the front panel.
- 16-bit analog output to a chart recorder (0-10 VDC or 0-20 mA).
- Relay setpoints can be programmed for PASS/FAIL applications, preventing
beam destruction.
|